Booking today · Houston service windows 9–12 · 1–4 · 4–7 Independent Bertazzoni specialists · Licensed & insured Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(713) 366-4775 Reserve a Visit
Model library · Bertazzoni Rangetop

PROF486GRTBXT

Bertazzoni PROF486GRTBXT Griddle Rangetop

Bertazzoni rangetop

Most common issues on this model

  1. Burner clicking but staying dark
  2. Griddle slow or patchy in its heating
  3. Grease channel clogged, backing up under the plate
  4. Flame lopsided or burner dropping out

On the PROF486GRTBXT, six sealed brass burners share a 48-inch Professional Series surface with an electric griddle. The griddle has its own heating element, apart from the gas burners, so the unit needs a gas line and an electrical connection. Like all rangetops, it is dropped into a counter and has no oven under it.

We treat the two halves separately. On the gas side we clean the ports, check cap fit and test the igniter at each burner. On the griddle side we measure the heating element, confirm the plate heats evenly and look at the grease channel, because a blocked channel backs grease under the plate. Gas odor means leaving the home and calling the gas utility.

A written price is given before we start, and our repairs have a 30-day workmanship warranty.

Key features

  • 48-inch gas rangetop
  • Six sealed brass MonoBloc burners, electronic ignition
  • Electric griddle on its own element
  • Cooktop only, for use with a separate wall oven
→Codes

Error codes this model can show

PROF486GRTBXTPROF486GRTBXT questions
Why does my griddle take so long to heat?

A weak heating element or a sensor that reads high can stretch the heat-up. We measure the element and test the sensor, and we also check the griddle's power connection.

Does the griddle work if the gas supply is off?

Yes, the griddle is electric and independent of the gas burners. If the gas is off, the burners will not work, but the griddle should still heat.

How do I keep the grease channel from clogging?

Scrape the plate while it is warm, let grease drain into the tray and empty the tray regularly. Cold, solid grease is what blocks the channel.

Book a visit

Book repair for your PROF486GRTBXT

Book in about a minute, or call the desk. Same-day windows inside the Loop on most days, next-day across the rest of Houston.