On Bertazzoni professional induction cooktops such as the PE244INDXV, PE304INDXV and PE365INDXV, E6 means the IGBT is overheating. The IGBT is the power switching part that drives the coil, and it gets hot at high power.…
On Bertazzoni professional induction cooktops such as the PE244INDXV, PE304INDXV and PE365INDXV, E6 means the IGBT is overheating. The IGBT is the power switching part that drives the coil, and it gets hot at high power. The official step is to wait until the cooktop has cooled down and switch it on again. Heating stops while E6 shows. The cooktop is protecting a part that works hard at high power levels.
1. Turn all zones off and wait for the cooktop to cool. 2. Keep the area under and around the cooktop clear for airflow. 3. Restart and use a lower power setting. 4. If E6 returns soon after cooling, call us.
It switches large currents to drive the induction coil, which creates heat. A cooling fan normally carries that heat away, and E6 means it has climbed too high.
Try a lower power level, especially for long boils. Spreading cooking across zones also keeps any one power stage from working so hard. That also reduces strain on the cooktop.
If it repeats after proper cooling with the vents clear, the cooling or the sensor may not be doing its job. We then test the fan and the readings.
A technician diagnoses it on site and gives you the price in writing before any work starts.